The ability for CLESEED CLECOOLV2 (クレクール 5) free-market policy air conditioner carrying around type drain hose 2M single phase 100V 50Hz 60Hz airconditioning 1,250W (4650BTU) rating power consumption 560W air conditioner dehumidification ventilation

$864.58 (¥ 94,500)*
15 items left
I approved it
I approved it
Please select options before adding to cart.
10X POINTS! Buy it and earn 9450 points!
About Points
*Actual price may vary according to exchange rates.
Payment will be charged in yen

Product Information



There are two kinds of lineups in CLECOOLV.
The main difference is a street of the following tables.


CLECOOL V2 CLECOOL V3
Type Carrying around type Carrying around separable type
Plane separation out of the room Impossibility Possibility
Automatic drainage Existence Existence
Hand-operated drainage Existence Nothing
Drain hose length
(the plumbing between the plane out of the room)
2M 3M
Weight 25.0 kg 26.0 kg

Function

●Air conditioner
I judge compressor movement from outside temperature and setting temperature and work.
When outside temperature arrives at the setting temperature, I change it to ventilation movement automatically and reopen air conditioner movement when outside temperature rises.
It is a mode planning an air conditioner and energy saving.

Time when setting temperature is lower than outside temperature: I operate a compressor and I cool it and work.
Time when setting temperature is higher than outside temperature (I agree): I turn off a compressor and I send air and work.

●Dehumidification
I cool it intermittently and work and dehumidify it.
The basic movement becomes the air conditioner, and the cold wind begins to blow at the same time, too.
As this continues dehumidification movement regardless of outside temperature, I can use this dehumidification mode when I want, anyway, to cool it and to work.

●The ventilation
I operate only a fan and circulate indoor air.
When I reached the temperature that I set in the air conditioner, it becomes the ventilation state temporarily and suppresses the electricity consumption.

●Auto (automatic mode)
It is the mode which automatically changes movement to the cause at outside temperature and setting temperature.
I regulate "quantity of wind" and, to temperature difference, balance indoor comfort and energy saving with choice of the "air conditioner" "ventilation".

When setting temperature is lower than outside temperature (difference of temperature size): "An air conditioner" "quantity of wind strong", で works.
When setting temperature is lower than outside temperature (the difference of temperature small): I work in "air conditioner" "quantity of wind".
Time when setting temperature is higher than outside temperature: "The ventilation" "quantity of wind weak", で works.

●Quantity of wind
"Weak", the "strong" "inside" is から choice, and the quantity of wind comes.
At the time of the automatic mode choice, the quantity of wind automatically regulates it to temperature difference.

●Temperature setting
I can regulate the setting temperature between 16 degrees Celsius - 31 degrees Celsius and can change it every by 1 degree Celsius.
When outside temperature arrives at the setting temperature at the time of "air conditioner" "auto" choice, I turn off a compressor and work in a ventilation state.
When outside temperature becomes higher than setting temperature, I automatically reopen the operation of the compressor.
Because most of the electricity consumption of this container become this compressor, I can anticipate a large energy saving effect by stopping it.
The electricity consumption is suppressed when I make it easy to make setting temperature a little high, and to get up in the state mentioned above.


Display indication

There are display indication and various operation buttons in the indoor unit front.
When the display switches it on, I turn on suddenly from the jet-black open place.


Remote control
It is attached to the remote control at current opportunity.
The setting of the timer is possible other than reshuffling and the temperature setting of the mode from remote control, too.

●On timer / off timer
When the time when I set it passes, power supply ON/OFF is automatically performed.
I have the usage such as what I operate before use and return absent from beforehand.

About drainage
When the air conditioner operates an air conditioner, water occurs.
This plane saves the water which occurred in the tank in the indoor unit once.
When I turned off time and the power supply that a tank is filled with water, I drain the outdoor unit side of water automatically.
As this automatic drainage draws water with a pump and drains it of water, it is not necessary to usually touch pitch differences in the setting place of the room outside machine like an air conditioner.
The automatic drainage hose lengthening from an outdoor unit is approximately 1m.
In addition, the hand-operated drainage hose which can drain the indoor unit side of water by manual operation in CLECOOL V2 carrying around type is accompanied.

About the panel kit for the window (standard accessories)
It is attached the panel kit for the window to be able to more easily put a drain hose through this plane.
I put a drain hose in the panel kit for this window and can cut off the simple space by putting it between the gaps of the window.
Because the panel kit for the window slides with these two pieces in 64cm in height, Class two pieces of 10cm in width, the gap can regulate length in total.
In the thing using this kit, I can introduce it into vehicle installation and a ship, the places where it seems to have difficult setting of the air conditioner including the simple warehouse such as campers.
For the person who is attached two pieces of panel kits, but lacks length morePanel kit for the extensionI prepare もご.

※I may not fix the panel kit for the window by an installation place and the situation in a thing for the purpose of the assistance to put a drain hose through the gap to windows well to the last. I make this kit on the walls, and the laborers such as accessories come to need it.


Product explanation
It is free-market policy air conditioner, CLECOOLV2 (クレクール 5 carrying around type drain hose 2M) of クレシード.
CLECOOLV is the compact air conditioner which had ability for airconditioning of 1,250W from the small appearance.
As it is more compact than a normal air conditioner and is light, and placing it on the floor can use an indoor unit, an outdoor unit together, I can easily carry it and can use it in a place to like. In addition, it does not cost the installation expense as the construction is unnecessary.
In addition, I make use of the point where there is the carrying around and cross how to use including ahead and a villa, a festival and the use between the short terms including the stand and the common use with the other room to many divergences in leisure.
I can use it the outdoors without the power supply if I combine it with a generator and sine wave inverter let alone the standard home as it is a 100V power supply.

There are two kinds in クレクール 5, and there is a characteristic each.
Look at "the difference of the following part in CLECOOLV2 / CLECOOLV3".


Main specifications
The rating voltage: Single phase 100V
A frequency: 50Hz/60Hz
Moment max power: 2,120W / 60Hz
         2,060W / 50Hz
Ability for airconditioning: 1,250W (4650BTU)
Ability for dehumidification (27 degrees Celsius RH60%): 25L/day
A refrigerant: R140A
Body dimensions: Indoor unit 408*400*208mm
       Outdoor unit 514*400*208mm
Body weight: 25.0 kg
Drain hose length: 2M
Drainage hose length: 1M
Power supply cable length: 1.5M

Instructions
●There is the cool thyme of approximately three minutes in this plane after a compressor stop. During cool time, this plane does not operate a compressor.
●When ability for airconditioning declines remarkably, I can fill refrigerant gas, but the tool for exclusive use of the technical knowledge shop is necessary for filling of the refrigerant gas. Please depend toward the specialties such as the air-conditioner maintenance on this occasion.

About difference in CLECOOLV2 / CLECOOLV3
I usually have characteristics unlike the domestic setting type air conditioner with me in CLECOOLV.
The connection of an indoor unit, the outdoor unit is done by initial state, and CLECOOLV is in a condition to be filled the refrigerant gas.
In addition, placing it on the floor can just use an indoor unit, an outdoor unit together, and it is not necessary to fixedly mount it on the walls.
Therefore, I can just manage it when I perform setting of constructing it and can introduce even the air conditioner setting that there is not experience willingly.
I make use of this advantage, and two kinds of types are in CLECOOLV.

CLECOOLV2 (drain hose 2m carrying around type)
I can easily carry it and am the type that I move it willingly, and the place that wants to use the air conditioner can apply.
As there is a handle, it is easy to lift it and if it is an adult male, I do not have any problem alone and can carry it.
Physical strength can carry one with the confidence in the women!
As I can use it if there is even a place to put a power supply and this plane, I can use even not only the room but also outdoor or the tent.
I make use of the point that can carry it and cross how to use including short-term use and the common use with the other room to many divergences.
The manual operation drainage hose which can drain it of water about the drainage in a favorite timing is accompanied.

(only in hand-operated drainage hose CLECOOL V2)

CLECOOLV3 (drain hose 3m carrying around separable type)
Such as the setting type air conditioner is the type that can separate the plane out of the room to be easy to fixedly mount it.
Setting that I put a drain hose through the pass-throughs in what an indoor unit and an outdoor unit can separate becomes easy.
I show the true value by camper, movement sale car, ship which is too big, and has difficult setting with the normal setting type air conditioner.
In addition, I can introduce even the places that there is not willingly even if I do the full-scale setting construction including the office container of a villa and a farming warehouse, the construction spot.
The separation / connection work of an indoor unit, the outdoor unit is not difficult, too and can easily perform it.
(when I have access to separation / and work, some refrigerant gas may leak out.)

(state before separating)
(the state that separated, and took off a drain hose)

Recently Viewed Products

See All >

Shipping Options

JP Post EMS

JP Post EMS Your order will be shipped to you via Japan Post EMS. Japan Post is a speedy delivery service that delivers to more than 120 countries. With an effective tracking system and insurance program, EMS is able to offer a secure delivery worldwide. You can track your package with the tracking code provided and it will be delivered within a week. See estimated shipping fee

Payment Methods

Available Payment Methods

  • Credit Card
  • PayPal
  • Alipay

Remarks

Credit Card, PayPal, Bank Transfer, Alipay

Credit Card We accept credit and debit cards.
The following credit and debit cards can be used:


•Visa
•MasterCard
•American Express
•JCB
•others
PayPal
We accept PayPal.
After receiving the order confirmation e-mail, there will be another e-mail titled "[creeronlineshop] Payment Notification" sent to you.Please proceed with the PayPal payment by the link in that e-mail.
The total amount that you need you pay for is:
the amount of all items + the shipping fee via EMS
Notice
*Please note that if payment through PayPal is not confirmed by the date indicated in the e-mail, your order will be automatically cancelled.
Bank Transfer We accept Bank transfers.
fter receiving the order confirmation e-mail, please transfer your payment to the bank account specified in the e-mail.
The total amount that you need you pay for is:
the amount of all items + the shipping fee via EMS + transfer commission

Notice
*All payments are made in Japanese Yen. Please check with your bank for applicable exchange rates.The commission will be paid by you.
*If payment by bank transfer is not confirmed within the date indicated in the e-mail, your order will be automatically cancelled.
Alipay We accept Alipay.
The “Payment Amount” is calculated as below.
The total amount that you need you pay for is:
the amount of all items + the shipping fee via EMS
Upon confirming your order, we will send you a link to make a payment via Alipay’s secure payment page.
You must finish the payment process before the deadline to complete your order.
Please check the payment process from the link here.

https://global.rakuten.com/en/help/payment/alipay_pc.html
https://global.rakuten.com/en/help/payment/alipay_mobile.html

Notice
*Please note that if payment through Alipay is not confirmed by the date indicated in the e-mail, your order will be automatically cancelled.

Return Policy

Cancelation/Return and Refund Policy
*Considering about the difference between Japanese cars and foreign cars,we couldn't garantee the compatibility completely even if the product
fits Japanese cars perfectly.So please purchase it on understanding because no merchandise can be returned.

*In some cases, a duty may be caused by a country.In that case,please approve it beforehand because it becomes the visitor burden.


Thank you very much for your cooperation in advance.
×

Not available for Overseas shipping

This product cannot be shipped to Us United States from the store.

Please contact the store for further information.

×

Delivery Rates : EMS (International Express Mail Service)

Ship to
Shipping Option
Note: Exchange rates are for reference only.
Back to Top