Product Information

S8JX-P05005C (DC5V)
S8JX-P05012C (DC12V)
S8JX-P05024C (24 v DC)
S8JX-P05048C (DC48V)

[Manufacturer] OMRON (Omron Corporation)
[Model number]
 S8JX-P050 * C
[Product name] switching, power supply
[Series] S8JX
[Input]
 AC100 ~ 240v free input
 (DC80 ~ 370 V * 1)
[* 2] 50 W
Output voltage and output current
 DC5V / 10A
 DC12V / 4.2 A
 DC24V / 2.1 A
 DC48V / 1.1 A
[Structure]
 Cover type
 Front mounting type
[Internal fans, nothing
Comes with full chamfer on metalwork
♦ * contains the specified symbol.
♦ 05 (DC5V), 12 (DC12V), 24 (24 v DC), 48 (DC48V)
♦ * 1 EC and AC 100 ~ 240V (AC 85-264 V) is the scope of application of the safety standards (UL, EN, etc.).
♦ * When overcurrent protection the power supply does not start if the connected loads with built-in 2 DC-DC converter, in the selection of capacity Please note.

Rating

[Efficiency]
 V type: 73%
 12V type: 76%
 24 V type: 77%
 48 V type: more than 80%
On the input conditions
 Voltage range * 1 AC 100 ~ 240V (acceptable range AC 85-264 V, DC80 ~ 370 V * 8)
 Frequency * 1 50 / 60 Hz (47-63 Hz)
 Current * 2
 -AC100V input at::0.75A less
 -AC200V input at::0.4A less
 Power factor 0.9 or higher
 Harmonic wave current regulations EN61000-3-2
 Leakage current * 2
 -AC100V input at::0.5mA less
 -AC200V filling: 1 mA or less
 Inrush current (25 ° C, cold start) * 2
 -AC100V input at::17.5A less
 -AC200V entered: 35 a
[Output characteristics * 3]
 Voltage variable range * 4-10 ~ by +15%(v,Adj) (48 V type is ± 10%)
 Ripple noise voltage * 2 2%-to-ambient temperature below 0 ° C time to less than three percent (p-p) (V type only)
 Input fluctuations less than 0.4% (input voltage in the AC)
 Load change 0.8% or less (at rated input load 0-100%)
 Temperature changes 0.05% / ° C or less (input rated at)
 Startup time less than 1000 ms
 Output hold time * 2 at least 20ms
[Whistles]
 Overcurrent protection 105-160%, drooping, intermittent operation, automatic reset
 Over voltage protection * 5 with
 Overheating protection without
 Parallel operation possible (However, driving can be backed up, an external diode required)
 Serial driver-friendly (up to two external diode required)
 Alarm display lamp radio
Derating curve reference ambient temperature manufacturers catalogs (However, no dew condensation or icing allowed)
The storage temperature-25-+75 ° C (However, no dew condensation or icing allowed)
Ambient humidity 25 ~ 85% RH (storage humidity 25-90%)
Withstand voltage
 AC3.0kV 1min (batch input) and (output in bulk) between (detection current 20 mA)
 AC2.0kV 1min (batch input) and (ground) between (detection current 20 mA)
 Ac1.0kV 1min (output in bulk) and (ground) between (detection current 20 mA)
And [resistance] 100 M Ω or more (output bulk) (bulk input and grounding) between at DC500V
Resistant vibrating 10-55 Hz, amplitude 0.375 mm each of 3 directions at 2 h no abnormalities
[Vandal] 150 m / s ^ 2 each 6-direction three times, no abnormalities in
[Output indicator] with (colour: green)
[Noise Terminal voltage * 2] EN55011 Group 1 Class B compliance, FCC Class B compliance * 8
Radiated interference field strength EN55011 Group 1 Class B compliance * 8
[Safety standards * 7]

 UL Listed:UL508 (Listing)
 UL UR:UL60950-1 (Recognition)
 cUL Listed:CSA C22.2 No,107,1
 cUR:CSA C22.2 No. 60950-1
 EN/VDE:EN50178 (= VDE0160) over voltage category III
 EN60950-1 (= VDE0805 Teil1) (PIN, DIN EN 50274 (VDE0660-514) compliant)
SEMI standards SEMI F47-0706 (AC200V filling)
[Mass * 6, 370 g
♦ * 1. There by the inverter output specification, output frequency 50 / 60 Hz and is listed as
♦ cause smoke and fire damage due to power supply's internal temperature rise, output of the inverter power supply power supply do not use.
♦ * 2. Rated input voltage (AC100V or AC200V), 100% load is provided.
♦ * 3. Output characteristics are provided at the power supply output terminal.
♦ * 4. Voltage variable range over voltage rises in the v,Adj volume operation.
♦ Please note and check the output voltage of the power supply if the output voltage is adjustable to the load it does not break.
♦ * 5. Return input turn OFF the third over after the input power to the power on again.
♦ * 6. Mass is open-front mounting type.
♦ * 7. EC directives and is AC 100 ~ 240V (AC 85-264 V) the scope of application of the safety standards (UL, EN, etc.).

Recently Viewed Products

See All >

Shipping Options

EMS

EMS

Payment Options

Credit Card

Credit Card We accept credit and debit cards.
The following credit and debit cards can be used:
•Visa
•MasterCard
•American Express
•JCB
•others

Return Policy

Any return or refund due to customers will not be accepted.
×

Not available for Overseas shipping

This product cannot be shipped to Us United States from the store.

Please contact the store for further information.

×

Delivery Rates : EMS (International Express Mail Service)

Ship to
Shipping Option
Note: Exchange rates are for reference only.
Back to Top