Product Information

AC 100-120 V (3 G NA-205B AC100/120)
AC 200-240 V (3 G NA-205B AC200/240 V)

[Manufacturer] OMRON (Omron Corporation)
[Category] solid state relay
[Format] G3NA-205B
Photo-coupler isolation method
[Zero-crossing function,
[Operation indicator' prevalence
[Output application load, 5A AC 24 ~ 240v * 2
In the voltage input
 AC100-120V
 AC200-240V
Note... earned in standard UL and CSA standards.
* 1. Is the value when you use the application load is specified radiator coated with silicone grease. Also depends on the ambient temperature.
* 2. Please load because the longer the time loss in the AC75V below.

Rating
♦ input (ambient temperature 25 ° C)
[Voltage]
 AC 100 to 120 V,
 AC200-240V
Using voltage range
 AC 100-120 V:AC75-132 V
 AC 200-240 V:AC150-264v
[Impedance * 1]
 AC 100-120 V:36 k Ω ± 20% 3
 AC 200-240 V:72 k Ω ± 20%
Select the voltage level
 Operating voltage
 -AC 100-120 V:AC75V below
 -AC 200-240 V:AC150V less
 Recovery voltage
 -AC 100-120 V:AC20V more
 -AC 200-240 V:AC40V more than * 4
♦ output
Rated voltage
 AC24-240V
Click the load voltage range
 AC19-264 V
[Load current * 5]
 Radiator and 0.1-5A (at 40 ° C) * 6
 No radiator 0.1 ~ 3A (at 40 ° C)
[On‑State discharge, 60 A (60 Hz, 1 cycle)
[Peak repetitive off collector-emitter voltage (reference value)] 600V(VDRM)
* 1. Input impedance is the maximum value of the voltage value. (Example. AC 100 to 120 V, AC120V value)
* 2. Constant current input circuit system-G 3NA-(D) 2 □ □ is 15 mA or less for the B-UTU type.
* 3. -G3NA-240B (-UTU) type is 72 k Ω ± 20%.
* 4. -G3NA-240B (-UTU) type is AC20V or more.
* 5. Depending on ambient temperature.
* 6. When the heat plate with heat-only or default size.

Performance
[Form] form g3na-206B
[Operating hours]
 Load power 1 / 2 cycle +1 ms or less (DC input)
 Load power 1 1 / 2-cycle +1 ms following (AC input)
Time to recover
 Load power 1 / 2 cycle +1 ms or less (DC input)
 Load power 1 1 / 2-cycle +1 ms following (AC input)
[Output-on voltage] CS 1.6 v (RMS)
[Leakage]
 5 mA or less (AC100V)
 10 mA or less (AC200V)
Insulation resistance 100 M Ω or more (500 V menu GA in)
Withstand voltage
 AC2, 500 V 50/60 Hz 1min
[Vibration] 10-55-10 Hz single amplitude 0.75 mm (double amplitude of 1.5 mm)
[Shock] 1000 m / s2
The storage temperature-30-+100 ° C (However, it freezes and no condensation)
Ambient temperature-30-+80 ° C (However, it freezes and no condensation)
Ambient humidity 45 ~ 85% RH
[Mass] 60 g

Recently Viewed Products

See All >

Shipping Options

EMS

EMS

Payment Methods

Available Payment Methods

  • Credit Card

Remarks

Credit Card

Credit Card We accept credit and debit cards.
The following credit and debit cards can be used:
•Visa
•MasterCard
•American Express
•JCB
•others

Return Policy

Any return or refund due to customers will not be accepted.
×

Not available for Overseas shipping

This product cannot be shipped to Us United States from the store.

Please contact the store for further information.

×

Delivery Rates : EMS (International Express Mail Service)

Ship to
Shipping Option
Note: Exchange rates are for reference only.