Shop Japan. We ship worldwide, bringing Japan directly to you.

 
[E5C2-R20K []]DIN-sized (48 x 48 mm) Temperature Controller with Analog Setting

OMRON E5C2-R20K [] Temperature Controller (Analog setting,ON/OFF,No indication,Relay) NN

Buy it and earn 134 points! About Points
$ 119.50 (¥ 13,456)
Actual price may vary according to exchange rates.
Payment will be charged in yen
Please select options before adding to cart.
Shipping Options: Details
EMS
Payment Options: Details
Credit Card

Product Information

[Product Name] Temperature Controller
[Model] E5C2-R20K
[Setting method] Analog setting
[Indication method] No indication
[Control mode] ON/OFF
[Output] Relay
[Input] Thermocouple , K (CA) Chromel vs. alumel
[Output / Minimum scale division] Model
: [0 to 200 / 5] E5C2-R20K AC100-240 0-200
: [0 to 300 / 10] E5C2-R20K AC100-240 0-300
: [0 to 400 / 10] E5C2-R20K AC100-240 0-400
: [0 to 600 / 20] E5C2-R20K AC100-240 0-600
: [0 to 800 / 20] E5C2-R20K AC100-240 0-800
: [0 to 1,000 / 25] E5C2-R20K AC100-240 0-1000

Ratings
[Supply voltage] 100 to 240 VAC 50/60 Hz
[Operating voltage range] 90% to 110% of rated supply voltage
[Power consumption] Approx. 3.6 VA
[Input] Thermocouple (with sensor burnout detection circuit)
[Control method] ON/OFF
[Setting method] Analog setting
[Indication method]No indication
[Control output] Relay output: SPDT, 3 A at 250 VAC, resistive load (switching capacity: 330 VA)
[Ambient operating temperature]-10 degree to 55 degree (with no icing or condensation)
[Ambient operating humidity] 45% to 85%
Note: Do not use an inverter output as the power supply.

Characteristics
[Setting accuracy] +-2% FS max.
[Hysteresis] Approx. 0.5% FS (fixed)
[Proportional band] 3% FS (fixed)
[Control period] Approx. 20 s
[Reset range] 5 +-1% FS min. (*1.)
[Insulation resistance] 20 M Ohm min. (at 500 VDC)
[Dielectric strength] 2,000 VAC, 50/60 Hz for 1 min between charged terminals and uncharged metallic parts
[Vibration resistance]
: [Malfunction] 10 to 55 Hz, 0.15-mm single amplitude for 10 min each in X, Y, and Z directions
: [Destruction] 16.7 Hz, 2-mm double amplitude for 2 hrs each in X, Y, and Z directions
[Shock resistance]
: [Malfunction]: 147 m/s^2, 3 times each in 6 directions
: [Destruction]: 294 m/s^2, 3 times each in 6 directions
[Life expectancy] Electrical: 100,000 operations min. (3 A at 110 VAC,resistive load)
[Weight] Approx. 100 g (with flush-mounting adapter)
[Degree of protection]
: [Front panel]: IEC standard IP40
: [Terminals]: IEC standard IP00
[Applicable Socket(order separately)] P2CF-08 ,P3G-08
[Applicable Protective Cover(order separately)] Y92A-48B
Note: *1.
No reset function is incorporated by any E5C2 model with ON/OFF control.
The reset function is used to correct offset for proportional control. If there is an offset below the set value, turn the reset adjustment clockwise.

Recently Viewed Products

See All >

Shipping Options

EMS

EMS

Payment Options

Credit Card

Credit Card We accept credit and debit cards.
The following credit and debit cards can be used:
•Visa
•MasterCard
•American Express
•JCB
•others

Return Policy

Any return or refund due to customers will not be accepted.
×

Not available for Overseas shipping

This product cannot be shipped to Us United States from the store.

Please contact the store for further information.

×

Delivery Rates : EMS (International Express Mail Service)

Ship to
Shipping Option
Note: Exchange rates are for reference only.
Back to Top